Gamewell-FCI ILI95-S-E3 Intelligent Interface - Apollo Protocol
The Gamewell-FCI Intelligent Loop Interface95-Main Board (ILI95-MB-E3) is the main circuit interface for the following E3 Series® Systems using the Apollo Protocol SLC devices.
• E3 Series® Expandable Emergency Evacuation System
• E3 Series® Combined Fire and Mass Notification System
With its state-of-the-art 32-bit RISC processor, this compact “panel on a board” provides a powerful addition to Gamewell-FCI’s single-pair conductor solutions.
This intuitive design provides the following features:
These features, combined with a built-in network and serial protocols, allow this module to support a host of new and existing products, resulting in a building block approach to the fire alarm control panel design.
The ILI95-MB-E3 provides two signaling line circuits and terminals for the connections to up to 126 Apollo detectors and modules per SLC.
The RS-485 interface can support up to a total of six LCD-E3 and sixteen ASM-16 and/or sixteen ANU-48 remote LED driver modules.
The ILI95-MB-E3 is network ready and occupies 64 nodes, operating at 625K baud. In addition, the Addressable Node Expander (ANX) board expands the network to 122 nodes. When this sub-assembly is integrated with proven Broadband components, the result is a flexible yet powerful integrated audio solution.
When the sub-assembly transmits to remote locations, the optional RPT-E3 provides the ILI95-MB-E3 with valuable signal boosting and transient protection, as well as provides connectivity using both wire and fiber-optic cables.
The ILI95-MB-E3 relay outputs include system alarm, supervisory, and system trouble contacts.
The ILI95-MB-E3 provides output for a local energy city master box or for a remote location which is non power-limited.
All other wiring is Class 2 power-limited.
FEATURES & BENEFITS ILI95-MB-E3/ILI95-SE3:
• Listed under UL® Standard 864, 9th Edition.
• Listed under UL Standard UL2572 for Mass Notification.
• Provides network-ready integral 625K baud ARCNET.
• 115.2K baud RS-232 Signaling line circuits with:
• 2 Class A, Style 6, 7* or Class B, Style 4 circuits
• 40 Character user-defined text per device.
• Capacity of 126 analog/addressable Apollo devices per loop.
• 4100 Event History Log *Style 7 wiring requires the use of XP95-LI Isolator Modules.
ILI95-MB-E3 Only:
• 2 notification appliance circuits, Class “A”, Style Z or Class B, Style Y rated at 2.0 amps. per circuit.
• RS-485 supporting 16 ASM-16 switch modules and/or ANU48 LED driver modules
• Alarm, trouble, and supervisory dry contacts Form “C”, rated at 2 amp. @ 30 VDC (resistive).
• Supports six local/ remote LCD-E3 annunciators and five LCD-7100/RAN-7100 remote LED annunciators.
• two signaling line circuits.
• auxiliary relay functions.
• two notification appliance circuits.
• auxiliary power output.
• local energy city box output.